Call now – (02) 9586 3111

Accessible Reception Desks and Counters in NSW: What the Code Requires and What Good Design Adds

The reception or service counter is the first point of contact for many building users. The National Construction Code Deemed-to-Satisfy access provisions do not set a mandatory counter height, yet a counter that people cannot use is a common source of complaints under the Disability Discrimination Act. This page separates what the code requires from what good design adds, and gives the detailing checklist joiners and designers need for NSW projects under NCC 2022 Amendment 2.

Is a reception counter covered by the NCC?

NCC 2022 Volume One Part D4 and the Disability (Access to Premises – Buildings) Standards require an accessible path of travel to the counter and adequate circulation space in front of it. Where the public is screened from the service provider (for example by a glazed screen at a council counter, pharmacy or ticket office), Part D4 also requires hearing augmentation. The Deemed-to-Satisfy provisions do not set a height for the counter itself. NSW continues to apply NCC 2022 Amendment 2 until 1 May 2027. The Premises Standards reference AS 1428.1:2021 from 29 July 2025. For the current edition of AS 1428.1 see AS 1428.1 2009 versus 2021.

Why counters still matter: the DDA and the Premises Standards

Compliance with the Premises Standards is a defence only for the matters the Standards cover. A counter that excludes customers can still form the basis of a complaint under the Disability Discrimination Act 1992. Designers and building owners therefore treat accessible counter design as both a code matter and a DDA risk-management matter. For more on complaint prevention see a practical guide to DDA complaints prevention and DDA action plans for building owners.

Accessible counter checklist (AS 1428.2 basis)

AS 1428.2 provides the design guidance used for accessible reception and service counters. The table below lists the elements that should be checked on joinery drawings and at pre-occupation inspection. Exact figures and clause numbers must be confirmed in the current edition of AS 1428.2 before detailing. Older industry guidance has quoted a lowered section in the range 830–870 mm high and at least 800 mm wide; verify every dimension against the Standard.

ElementRecommendationCheck on drawings
Lowered section heightWithin the range set by AS 1428.2 for a frontal approachDimension the customer-side surface
Minimum lowered widthWide enough for one person (verify in Standard)Show clear width free of equipment
Frontal approach and knee/toe clearanceKnee and toe space under the lowered section so a wheelchair user can approach from the frontSection through the counter showing clearances
Circulation space in frontSpace for a wheelchair to approach and manoeuvrePlan dimension clear of queue barriers
Writing / signing surfaceUsable from the lowered sectionLocate and dimension
Reach to EFTPOS and pensWithin reach from the frontal approachShow fixed equipment positions
Lighting and glareAvoid glare that prevents lip-readingNote lighting direction
Contrast of counter edgeVisual contrast for people with low visionSpecify finish contrast

Related element checklists include light switches and power points under AS 1428.1.

Transaction counter versus staff work surface

The accessible part of the counter is the customer side: a lowered section that a seated person can reach face to face, with clear knee space underneath. The staff side can be set at a height that suits the staff's own work and ergonomics. It should not block eye contact, lip-reading or the passing of documents and payment terminals across the lowered section. AS 1428.2 addresses the customer-side approach; the staff side is primarily a workplace ergonomics question.

Hearing augmentation at screened counters

Where the public is screened from the service provider, NCC Part D4 requires hearing augmentation. In practice this applies to glazed screens at council customer-service counters, pharmacies, banks, ticket offices and similar locations. Signage indicating the availability of the system is also required. For the full requirements see hearing augmentation under NCC D4D8 and hearing loop installation in compliant venues.

Counters by building type

Medical and allied-health reception

Medical reception counters often combine a lowered section with privacy screens. Confirm both the approach clearances and any hearing augmentation triggered by screening. See also hospital access reports in NSW.

Hotel and serviced-apartment front desks

Hotel front desks frequently include high sections for standing use and a lowered section for seated users. The lowered section must remain free of luggage scales and brochure displays that block the approach.

Council and government customer-service counters

These often have glazed screens. Hearing augmentation and a clear frontal approach are the usual points raised at pre-occupation inspection.

School front offices

School reception counters serve both staff and visitors. The lowered section should remain usable during busy arrival and departure periods.

Gyms and leisure centres

Gym reception counters often sit near equipment displays. Keep the lowered section clear of promotional material and ensure the approach is not blocked by freestanding racks.

Retail and bank teller counters

Teller counters with screens require hearing augmentation. The writing surface and payment terminal must be reachable from the lowered section.

Common fails we see on NSW fit-outs

Sydney Access Consultants checks these items on joinery drawings at design audit and measures the finished counter at pre-occupation inspection.

Refurbishing an existing counter

Common retrofit options include adding a lowered wing, replacing a modesty panel with open knee space, relocating payment terminals to the lowered section, and providing a portable hearing loop where a permanent system is not practical. Confirm whether a portable system satisfies the NCC requirement in the particular location. See best access upgrades for public buildings for related retrofit guidance.

How Sydney Access Consultants reviews counters

At design audit we review joinery and fit-out drawings against AS 1428.2 and the NCC Part D4 requirements. At pre-occupation inspection we measure the installed counter, check knee clearances and confirm hearing augmentation where it is required. For a design audit or access report call (02) 9586 3111 or see disability access reports for DA and CC.

Frequently asked questions

Is there a mandatory reception counter height in Australia?

Not in the NCC Deemed-to-Satisfy access provisions. The NCC and the Premises Standards cover the accessible path to the counter and, where staff are screened from the public, hearing augmentation at the counter, but they do not set a counter height. Designers use AS 1428.2 as the reference for an accessible lowered section because a counter that customers cannot use can still lead to a complaint under the Disability Discrimination Act.

How high should an accessible reception counter be?

AS 1428.2 recommends a lowered section of the counter within a set height range, wide enough for one person, with knee and toe space underneath so a wheelchair user can approach from the front. Older industry guidance quotes 830–870 mm high and at least 800 mm wide. Check the exact figures in AS 1428.2 before detailing.

How high should the transaction counter be versus the staff work surface behind it?

The accessible part is the customer side: a lowered section that a seated person can reach face to face, with clear knee space. The staff side can be set for the staff's own work and ergonomics, but it should not block eye contact, lip-reading or the passing of documents and payment terminals across the lowered section. Sydney Access Consultants checks both sides of the counter at design audit.

Does a counter need a hearing loop?

Where the public is screened from the service provider, NCC Part D4 requires hearing augmentation. Confirm the exact trigger and any signage requirements in the current NCC for the project location.

Call (02) 9586 3111 for a design audit or access report.