Call now – (02) 9586 3111

Accessible entrances under NCC D4D3: what NSW buildings must provide

If you are designing a new building, planning a fit-out or answering a certifier's RFI, the first access question is usually the entrance. The main entrance is not a place for a detour. Under clause D4D3 of the current NCC (NCC 2022 in NSW), the principal pedestrian entrance must always be accessible, at least half of all pedestrian entrances must be accessible, and on larger buildings no inaccessible entrance can be far from an accessible one. This guide from Sydney Access Consultants explains the rules in plain words, with examples. Call (02) 9586 3111.

Getting to the building: the boundary, car parking and linked buildings

Before the door, there is the route to it. D4D3 requires an accessway to a building that must be accessible from three places: the main points of pedestrian entry at the allotment boundary, any required accessible car parking space on the allotment, and any other accessible building connected by a pedestrian link.

That means the footpath entry, the car park and the covered walkway all need a continuous step-free route, built to AS 1428.1. Where the ground falls, the route may need a walkway or a ramp; our guide to ramp gradients explains the options. It is one part of the wider rules in NCC Part D4.

Which entrances must be accessible

In a building required to be accessible, D4D3 requires an accessway through:

Entrances that serve only areas exempted under D4D5, such as some plant and service areas, do not need to be accessible. See our guide to D4D5 exemptions.

The ABCB guidance explains why the principal entrance is singled out: it is the entrance most people use, and in hotels, theatres and public buildings it is often the ceremonial one too. The guidance also says a ramp or lifting device should sit close to the steps it bypasses and close to any drop-off point or taxi rank. A ramp round the back is a second-class welcome.

Some examples of how the count works:

Entrances with several doorways, and double doors

A single entrance often has more than one doorway, such as a bank of glass doors. Where an entrance that must be accessible has up to three doorways, at least one must be accessible. Where it has more than three, at least half must be accessible. The doorways count as one entrance when they serve the same part of the building and sit no further apart than the width of the widest doorway.

Double doors catch many designs out. Where a doorway on an accessway has a manually operated pair of doors, the NCC requires one leaf on its own to give a clear opening of at least 850 millimetres, in accordance with AS 1428.1. Two narrow leaves do not make one accessible door. Automatic doors are treated differently, and the clear width can come from both leaves together.

The door is only part of the picture. Circulation space, hardware, thresholds and glazing markings all matter; see our guides to door circulation space, visual indicators on glazed doors and tactile ground surface indicators.

Existing buildings: the "affected part" and the entrance

For new work in an existing building, the Disability (Access to Premises - Buildings) Standards 2010 add a twist. When a building is extended or a new part is created, the principal pedestrian entrance of the existing building, and the path from it to the new work, generally become the "affected part" and must be brought up to the access requirements. That is why a tenancy fit-out or an extension can end up including an entrance upgrade that was never on the drawings.

There are limits. A concession applies where a lessee carries out work in a building they do not own, and other concessions exist for some existing features. The details turn on the project, so check them early. Where an entrance genuinely cannot be fixed, for example on a heritage frontage or a steep site, the tools are an access Performance Solution or an unjustifiable hardship case. Our guides to fit-outs and change of use, existing building access audits and heritage access Performance Solutions explain more.

On fit-outs in older strip shops, we often find the principal entrance is the real cost item, so we flag it at the start, before the tenant has budgeted only for the inside.

What Sydney Access Consultants checks

When Sydney Access Consultants reviews entrance designs at DA stage, the most common fix is not the door at all but the level change in front of it: a step or a steep forecourt that the architecture has made hard to ramp. We prepare DA and CC access reports for commercial, retail, health, education and residential buildings across NSW.

Gary Finn is an Accredited Member #435 of the Access Consultants Association. Our free initial consultation is a plan review. To have an entrance layout checked, call (02) 9586 3111.

First published by Sydney Access Consultants at https://sydneyaccessconsultants.com.au/accessible-entrances-ncc-d4d3-nsw.html.

Common questions

Which entrances must be accessible under the NCC?

Under clause D4D3 of the current NCC, a building required to be accessible must have an accessway through the principal pedestrian entrance and through at least 50% of all pedestrian entrances, including the principal one. In a building with a total floor area over 500 square metres, an inaccessible pedestrian entrance must not be more than 50 metres from an accessible one. Entrances serving only areas exempted under D4D5 are excluded.

Can the accessible entrance be at the side or back of the building?

Not instead of the principal entrance. The NCC requires the principal pedestrian entrance to be accessible in all cases, because it is the entrance most people use. A side or rear entrance can count towards the 50% total, but it cannot replace the main one. ABCB guidance also says ramps or lifts at an entrance should be close to the steps and to any drop-off point.

How does the 50 metre rule work?

It applies to buildings with a total floor area of more than 500 square metres. Any pedestrian entrance that is not accessible must be within 50 metres of an accessible pedestrian entrance, so people are not sent a long way around the building. On large sites with entrances on different streets or levels, check the distance for each inaccessible entrance early. Sydney Access Consultants checks this at DA stage.

Do double doors at an entrance need to be accessible?

If the doorway is on an accessway and has a manually operated pair of doors, one leaf on its own must give a clear opening of at least 850 millimetres, as the NCC states. A person should not need to open both leaves. Automatic doors may provide the clear width using both leaves. Where an entrance has several doorways, at least one, or half if there are more than three, must be accessible.

Does a shop fit-out mean the building entrance must be upgraded?

Often, yes. Under the Disability (Access to Premises - Buildings) Standards 2010, new work in an existing building can make the principal pedestrian entrance and the path to the new work an "affected part" that must be upgraded. There is a concession for a lessee doing work in a building they do not own. Unjustifiable hardship or a Performance Solution may apply. Call (02) 9586 3111 to check your project.

What if the existing entrance has steps that cannot be removed?

Options include a ramp, a platform lift, regrading the forecourt, or making another entrance the principal one if it genuinely is. Where none is reasonable, for example on a heritage frontage, an access Performance Solution or an unjustifiable hardship case may be considered. Sydney Access Consultants assesses the options and prepares the report the certifier needs. Our free initial consultation is a plan review.

© Sydney Access Consultants 2026. This article may not be reproduced without written permission.