Wheelchair seating spaces in NSW theatres, cinemas and halls (NCC D4D10)
If you are designing or refurbishing a theatre, cinema, auditorium, school hall, lecture theatre or place of worship with fixed seating, the NCC sets how many wheelchair seating spaces you need, how they are grouped and where they can go. Counting the wheelchair spaces is the easy part; placing them is the real test. This guide from Sydney Access Consultants explains clause D4D10 of the current NCC (NCC 2022 in NSW) in plain words, with worked examples, for architects, builders, certifiers and venue owners. Call (02) 9586 3111.
When D4D10 applies
Clause D4D10 applies where fixed seating is provided in a Class 9b assembly building. In practice that covers theatres, cinemas, concert and performing arts venues, auditoriums, lecture theatres, school halls with fixed or tiered seating, places of worship with fixed pews, and grandstands. It is one part of the wider access rules in NCC Part D4.
A hall or function room with loose, stackable chairs does not trigger the wheelchair seating count. That does not mean access can be ignored. The NCC still requires access to and within the areas people normally use, and the Disability Discrimination Act still applies to how the venue is run. Retractable or telescopic seating sits in between, so agree the approach with your certifier at DA stage rather than at the RFI.
The NCC also says access need not be provided to tiers or platforms of seating that contain no wheelchair seating spaces. The tiers that do contain spaces need a continuous step-free route from the entrance, which is why the location of the spaces drives so much of the design.
How many wheelchair seating spaces you need
The count is set by Table D4D10 and is worked out for each room or space with fixed seating. In our own words:
- Up to 150 fixed seats: at least 3 wheelchair seating spaces.
- 151 to 800 seats: 3 spaces, plus 1 more for every 50 seats, or part of 50, above 150.
- 801 to 10,000 seats: 16 spaces, plus 1 more for every 100 seats, or part of 100, above 800.
- More than 10,000 seats: 108 spaces, plus 1 more for every 200 seats, or part of 200, above 10,000.
Some worked examples show how the steps add up:
- A 120-seat lecture theatre needs 3 spaces.
- A 400-seat school hall with fixed seating needs 3 plus 5, so 8 spaces (250 seats above 150 is five lots of 50).
- A 1,000-seat theatre needs 16 plus 2, so 18 spaces (200 seats above 800 is two lots of 100).
The size of each space and the clear approach to it come from AS 1428.1, which the NCC calls up. We check each space and its approach against the AS 1428.1 wheelchair seating provisions, rather than relying on a generic block on the drawings.
Grouping: singles, pairs and maximum group sizes
Table D4D10 does not only set a number. For each size band it requires a minimum number of single spaces and a minimum number of groups of two, and above 150 seats it caps the size of any other group (5 spaces, or 10 in venues above 10,000 seats). The intent is simple: a person using a wheelchair should be able to sit with a friend or in a small group, not only in one wheelchair area at the side.
Companion seats beside each space are not a separate NCC count, but they are good practice and a sensible way to reduce discrimination risk. We recommend showing them on the seating plan.
Where the spaces can go
In venues with more than 800 fixed seats, the spaces must represent the range of seating provided. The ABCB guidance to the NCC says amenity, proximity to facilities, sightlines and pricing should be taken into account, and that putting every space in a single location would not be acceptable where fixed seating is provided. A wheelchair space at the back row is a seat, not a choice.
Cinemas have an extra rule. In a cinema with 300 seats or fewer, wheelchair spaces must not be in the front row. In a cinema with more than 300 seats, at least 75 per cent of the required spaces must be in rows other than the front row.
Spaces can be created with removable seats, so standard seats can be fitted when the space is not booked by a wheelchair user. The ABCB guidance accepts this, but the venue's booking and set-up practices must not discriminate, for example by selling those positions to general patrons too early.
Do not forget the stage, back of house and amenities
In a Class 9b assembly building, access is required to the areas normally used by the occupants. The ABCB guidance names stages, change rooms, orchestra pits and offices in theatres and concert halls. If the stage has no step-free route, the performer is excluded too. A ramp or a platform lift to the stage is often left off early drawings; see our guide on when a lift is needed.
The same rooms usually trigger other access items: hearing augmentation where an inbuilt amplification system is provided, accessible toilets and ambulant facilities nearby, and braille and tactile signage. Checking them together avoids a second round of drawing changes.
Existing and heritage venues: when a Performance Solution is needed
Older halls, churches and theatres often have raked floors, steep tiers, narrow aisles or heritage fabric that make the deemed-to-satisfy layout hard to achieve, especially in a refurbishment that keeps the existing tiers. In those cases an access Performance Solution can show how the Performance Requirement for access (D1P1 in NCC 2022) is met another way. It is prepared by the applicant's access consultant and assessed by the certifier.
On older halls and churches with raked floors or fixed pews, we often find the practical answer is a small number of well-placed level positions supported by a Performance Solution, rather than rebuilding the whole floor. Our guides to heritage access Performance Solutions and existing building access audits explain the wider process.
What Sydney Access Consultants checks at DA, CC and OC
- DA stage: the seat count for each room, the number and grouping of wheelchair seating spaces, how they are spread through the seating, and step-free routes to each tier with spaces and to the stage.
- CC stage: space sizes and approaches against AS 1428.1, the cinema front-row rule, the removable-seat strategy and any Performance Solution.
- Before the occupation certificate: an on-site check that the spaces are level, clear and have not been lost to added seats, speakers or equipment.
When Sydney Access Consultants reviews assembly spaces at DA and CC stage, the wheelchair space count is usually close; it is the location of the spaces and the step-free route to them, and to the stage, that most often needs a drawing change. We prepare DA and CC access reports for venues across NSW, including schools, university and TAFE campuses and places of worship.
Gary Finn is an Accredited Member #435 of the Access Consultants Association. Our free initial consultation is a plan review. To have a seating layout checked, call (02) 9586 3111.
First published by Sydney Access Consultants at https://sydneyaccessconsultants.com.au/wheelchair-seating-spaces-ncc-nsw.html.
Common questions
How many wheelchair seating spaces does a theatre need in NSW?
Under clause D4D10 of the current NCC, a Class 9b assembly building with fixed seating needs at least 3 wheelchair seating spaces for up to 150 seats. From 151 to 800 seats, add one space for every 50 seats or part over 150, so a 400-seat theatre needs 8. Above 800 seats the base rises to 16, plus one for every 100 seats or part over 800. Count each room or space separately.
Does D4D10 apply to a hall with stackable chairs?
No. D4D10 applies where fixed seating is provided in a Class 9b assembly building. A hall with loose or stackable chairs does not trigger the wheelchair seating count, but the NCC still requires access to and within the areas people use, and the Disability Discrimination Act still applies. Retractable or telescopic seating should be discussed with your certifier at DA stage. Sydney Access Consultants can advise on the approach.
Can all the wheelchair spaces be grouped at the back of the auditorium?
Not in larger venues. The NCC sets a minimum number of single spaces and pairs, and caps the size of any other group. Above 800 fixed seats, the spaces must represent the range of seating provided, and ABCB guidance says amenity, sightlines, proximity to facilities and pricing should be considered. Putting every space in one location would not be acceptable where fixed seating is provided.
Where can wheelchair spaces go in a cinema?
In a cinema with 300 seats or fewer, wheelchair seating spaces must not be in the front row. In a cinema with more than 300 seats, at least 75 per cent of the required spaces must be in rows other than the front row. The other D4D10 rules on numbers and grouping still apply, and the spaces themselves must comply with AS 1428.1.
Can removable seats be used to create wheelchair seating spaces?
Yes. ABCB guidance accepts removable seats, so the space can hold standard seats when it is not needed for a wheelchair user. The catch is management: the venue must make sure its booking and set-up practices do not discriminate, for example by releasing those spaces to general sale too early. Sydney Access Consultants can document the strategy for the certifier and the operator.
Does the stage need to be accessible?
Generally yes. In a Class 9b assembly building, access is required to the areas normally used by occupants, and ABCB guidance names stages, change rooms, orchestra pits and offices in theatres and concert halls. A ramp or platform lift to the stage is often left off early drawings. In existing or heritage venues a Performance Solution may be needed. Call (02) 9586 3111 for a plan review.
© Sydney Access Consultants 2026. This article may not be reproduced without written permission.