Ambulant toilets in NSW: when the NCC requires them, and when a Performance Solution can leave them out
Under NCC 2022 Amendment 2 Part F4, at each bank of toilets that has one or more toilets in addition to an accessible unisex toilet, at least one ambulant toilet must be provided for males and one for females, designed to AS 1428.1. It is the sanitary item most often missed on drawings and most often queried at construction certificate stage. NSW building work is assessed under NCC 2022 Amendment 2, which calls up AS 1428.1:2021, until NCC 2025 is adopted in NSW on 1 May 2027. Sydney Access Consultants prepares access reports and Performance Solutions; we are not the certifier. Call (02) 9586 3111.
What an ambulant toilet is, and who it is for
An ambulant toilet is a cubicle for people who walk but need physical support or extra room: older people, people using walking frames or crutches, and people with balance or strength limitations. It has grabrails on both sides, a suitable door and more space than a standard cubicle. It is not designed for wheelchair users, which is why it never replaces the accessible unisex toilet. For a fuller comparison of the two, see accessible toilets versus ambulant toilets. The design requirements sit in the ambulant provisions of AS 1428.1; we state them in our own words in our reports rather than reproducing the Standard.
When the NCC requires an ambulant toilet
The trigger in plain words
Clause F4D5 of NCC 2022 Amendment 2 asks for an ambulant compartment for males and one for females at each bank of toilets where there is one or more toilets in addition to an accessible unisex sanitary compartment at that bank. Put simply: if a location has an accessible unisex toilet and other toilets as well, ambulant cubicles are needed there. A location with only a single accessible unisex toilet does not trigger them.
What a "bank" means in practice
A bank of toilets is a group of toilets at one location. Where male and female facilities are at separate locations, or a storey has more than one group of toilets, each bank needs to be looked at. Accessible unisex toilets have their own distribution rules; see disabled toilet regulations NSW.
Three common layouts
- One accessible unisex toilet only, for example a small tenancy: no ambulant cubicle is triggered by that bank.
- An accessible unisex toilet plus male and female toilets at the same location: an ambulant cubicle is needed in the male facilities and one in the female facilities.
- Several banks on a floor: each bank with toilets in addition to an accessible unisex toilet needs its own ambulant provision. Check every bank, not just the main one.
Storeys without lift or ramp access
The NCC lets accessible unisex facilities be left off a storey that is not required to be served by a passenger lift or ramp. How that interacts with ambulant provision on that storey is a question to settle with the certifier early, because ambulant users can often manage stairs that wheelchair users cannot.
Counting rules that trip designers up
- An ambulant cubicle is not a unisex facility. Under F4D3 it cannot be counted towards both male and female fixture numbers.
- A required accessible unisex toilet can be counted once for both sexes. Extra accessible rooms provided beyond the requirement cannot be counted that way.
- No accessible path of travel is needed to an ambulant cubicle. The ABCB guidance notes that because the cubicle is not intended for wheelchair users, an accessible path to it is not required. It still needs its rails, door and circulation inside.
- Mirror-image accessible rooms. Where two or more accessible unisex facilities of a type are provided, left- and right-hand layouts should be split as evenly as possible.
Fixture numbers themselves come from the occupant numbers for the building's class under F4D4. See the NCC Part D4 access guide for how access and sanitary provisions fit together.
When a Performance Solution can leave ambulant toilets out
A Performance Solution is another way of meeting the NCC Performance Requirements. It is not an exemption. Our pages on what an NCC Performance Solution is and Performance Solutions explain the method.
The Performance Requirement
F4P1 requires suitable sanitary facilities, to the degree necessary, appropriate to the use of the building, the number and gender of the occupants, and the disability or other particular needs of the occupants. The question for an ambulant omission is whether people with an ambulant disability are still served at least as well.
Typical honest cases
- A workplace or facility that provides several accessible bathrooms, which offer more room and support than an ambulant cubicle, alongside limited male and female banks.
- An existing amenity block where an ambulant cubicle cannot fit without losing a required fixture.
- A small fit-out with a constrained footprint where the accessible rooms are close by and easy to find.
What the report must show
Who the ambulant user group is and how they are served: grabrails, door type and circulation in the alternative rooms, distance from the bank, and signage that directs people there. It must show the alternative is equal or better for that group, use a stated assessment method (usually a comparison with the Deemed-to-Satisfy intent plus expert judgement), and set out the limitations: this building, this layout.
When it will not work
When the alternative accessible rooms are on another storey or a long way from the bank; when the "alternative" is a standard cubicle with a single rail; or when the only reason is to save a cubicle.
Our experience
Sydney Access Consultants has prepared Performance Solutions for not providing ambulant compartments in male and female toilet banks where additional accessible bathrooms were provided. Ambulant provision sits on our list of access Performance Solutions that come up again and again.
What the certifier wants to see
- An amenities plan with each bank marked, the occupant numbers and the fixture count.
- The accessible unisex and ambulant provision for each bank, with door types.
- Where ambulant cubicles are omitted, a Performance Solution report with a performance-based design brief, the Performance Requirements, the method, the evidence and the limitations.
See what certifiers want in an access report.
Where it comes up most
- Gym and fitness fit-outs with change rooms; see gym NCC classification and access.
- Cafes, restaurants and bars; see restaurant and cafe access reports.
- Medical centres and clinics; see medical centre access reports.
- Highway service centres; see motorway service centre access.
- Schools; see school access reports.
NCC 2025 in NSW
NSW adopts NCC 2025 on 1 May 2027. A project is generally assessed under the edition in force when its construction certificate application is made, so confirm the edition with your certifier. NCC 2025 also brings changes to how all-gender facilities are treated; see NCC 2025 access changes in NSW and NCC 2025 all-gender sanitary facilities.
Answer-ready questions
When is an ambulant toilet required in NSW?
Under NCC 2022 Amendment 2 Part F4 (clause F4D5), at each bank of toilets where there is one or more toilets in addition to an accessible unisex sanitary compartment, at least one sanitary compartment suitable for a person with an ambulant disability must be provided for males and one for females, designed to AS 1428.1. A location with only a single accessible unisex toilet does not trigger an ambulant compartment.
Can an ambulant toilet count as a unisex toilet?
No. Under F4D3 an ambulant compartment is not a unisex facility, so it cannot be counted towards both male and female numbers. A required accessible unisex compartment can be counted once for both.
Does an ambulant toilet need an accessible path of travel?
No. An ambulant compartment is not designed for wheelchair users, so the NCC guidance says an accessible path of travel to it is not required. It still needs the AS 1428.1 ambulant features: grabrails, a suitable door and room to move.
Can a Performance Solution leave out ambulant toilets?
Sometimes. Where a building provides additional accessible bathrooms that serve people with an ambulant disability at least as well, a Performance Solution under F4P1 can justify not providing ambulant compartments in the male and female banks. The report must show the alternative is equal or better for that user group, that people can find it, and the limits of the solution. Sydney Access Consultants has prepared Performance Solutions of this kind.
How Sydney Access Consultants helps
We review amenities layouts at design stage, prepare DA and CC access reports (see access reports for DA, CC and CDC) and write Performance Solutions where ambulant provision cannot or should not follow the Deemed-to-Satisfy path. Gary Finn is an Accredited Member of the Access Consultants Association, member 435. Our practice concentrates on Cronulla, the Sutherland Shire and Hurstville; see Sutherland Shire access reports. Call (02) 9586 3111 for a fee. The free initial consultation is a plan review only.