Access reports for sports clubhouses, surf clubs and amenity buildings in NSW

A clubhouse, change-room building or amenity block is a public building used by players, spectators, families and volunteers. Many are rebuilt or upgraded with council or grant funding that asks how the project improves access. An access report for a clubhouse covers the path from the car park and field to the door, accessible and ambulant toilets, change rooms and showers, the function room and canteen, and spectator areas, and flags where a Performance Solution is needed. NSW building work is assessed under NCC 2022 Amendment 2 until NCC 2025 is adopted in NSW on 1 May 2027. Sydney Access Consultants prepares the access report and any Performance Solution; we are not the council or the certifier. Call (02) 9586 3111.

What class of building is a clubhouse?

A clubhouse with a function room or that serves a sports ground is typically a Class 9b assembly building, with change rooms, a canteen and storage as part of it. A stand-alone public toilet block may be classified differently. Each part is classified on its actual use, and the certifier makes the call. Our gym and gymnasium NCC classification page explains how sports-related classification works.

The accessible journey: car park, field, beach and building

Parking and the path to the door

Accessible car parking follows NCC D4D6 and AS/NZS 2890.6; see accessible car parking NSW. The report must show a continuous accessible path of travel from the accessible parking and any drop-off to the principal entrance. On sports grounds, the usual failure points are gravel or grass car parks, kerbs without kerb ramps, and a path that stops short of the door.

Towards the field or the beach

Paths to the field edge, spectator areas or the beach are commonly included in the project scope, even where they sit in council open-space or public-domain works rather than the building approval. Beach access matting and ramps at surf clubs are usually council items rather than NCC requirements, but they decide whether the new accessible facilities can actually be reached.

Level changes

Elevated surf clubs and older clubhouses often have level changes at the entry, the deck or the function room. Ramps, landings and handrails need to meet AS 1428.1 as called up; see wheelchair ramp gradients.

Toilets, change rooms and showers

How many toilets

For sports venues, the NCC's sanitary table counts participants and spectators separately, with closet pans, urinals and washbasins for each group. Accessible unisex toilets are then required under F4D6, and ambulant cubicles for males and females at each bank of toilets that has toilets in addition to an accessible unisex toilet. See disabled toilet regulations NSW.

Do the change rooms need accessible showers?

Part F4 ties the number of accessible unisex showers to showers the NCC itself requires, and the sports-venue sanitary table counts toilets, urinals and washbasins rather than showers. Where team showers are provided anyway, providing an accessible unisex shower, or an accessible change room with a shower, is the defensible approach under the Disability Discrimination Act and is commonly asked for by funders. A good access report says which basis applies, so nobody is surprised at construction certificate stage.

Change rooms that work for everyone

An accessible change room or cubicle needs circulation space, a bench at a usable height, hooks and lockers within reach, and a door that opens wide enough. Separate female or all-gender change provision is a design brief decision that affects layout; see NCC 2025 all-gender sanitary facilities.

Function room, canteen and spectator areas

Function room

Where an inbuilt amplification system is installed in a function room, hearing augmentation is required under D4D8; see hearing augmentation NCC. If the function room is upstairs, whether it must be reached by a lift or ramp depends on the Part D4 provisions and any exemption that applies; see the NCC Part D4 access guide.

Canteen and bar

A section of the canteen or bar servery used by the public should be on the accessible path at an accessible height. See restaurant and cafe access reports for counter and seating issues.

Spectator areas, signs and tactile indicators

Where fixed seating is provided in a Class 9b assembly building, D4D10 requires wheelchair seating spaces, positioned and grouped so wheelchair users can sit with family and friends. Grassed banks and informal viewing areas are a design brief matter. Stairs and ramps need tactile ground surface indicators (see TGSI compliance), and accessible toilets and exits need braille and tactile signs (see braille and tactile signage).

Does a new amenities block need a Changing Places room?

Usually not under the NCC. Clause F4D12 requires an accessible adult change facility, built to Specification 27, in a Class 9b sports venue only where it has a design occupancy of at least 35,000 spectators, or contains a swimming pool with a perimeter of at least 70 metres that is required to be accessible. A community clubhouse will almost never meet those thresholds.

Councils, funders and inclusion plans may still ask for one, or for an accessible change room with a hoist and an adult change table. That is a design brief decision, best made early because it affects the footprint. Changing Places branding has its own criteria. See accessible adult change facilities and, where a pool is involved, accessible swimming pools.

Existing and heritage clubhouses

Alterations trigger the new part plus the affected part: the principal pedestrian entrance and the accessible path from it to the new work. See change of use and fit-out access. Where a full upgrade is not reasonable, unjustifiable hardship may apply (see unjustifiable hardship), or a Performance Solution may be the honest path, particularly around retained fabric (see heritage access Performance Solutions and Performance Solutions). If no works are planned yet and the club or council wants to know where it stands, see access audits for existing buildings and council halls.

Planning pathway and grant evidence

Council works on community land may follow a different planning pathway from a private development application. Whichever pathway applies, the access report should assess the work against NCC Part D4 and Part F4 and the Premises Standards, so the council or club can show it met them, and the certification arrangements should be confirmed early.

Grant programs often ask how a project will improve access. A site-specific access report, or a review of the existing clubhouse, is evidence. A general statement that the building will be accessible is not.

Our experience

In 2018, Sydney Access Consultants prepared a set of access reviews for Kogarah Council (now Georges River Council), covering a School of Arts hall, a surf life-saving hall, community halls and centres and a senior citizens centre. Sydney Access Consultants has also undertaken South Coast council work including a showground Performance Solution and certification, and public amenities.

Answer-ready questions

What does an access report for a sports clubhouse cover?
It assesses the clubhouse against NCC Part D4, Part F4, AS 1428.1 and the Premises Standards: accessible parking and the path to the entrance, ramps and doors, accessible unisex and ambulant toilets, change rooms and showers, the function room and canteen, hearing augmentation where an amplification system is installed, signage and tactile indicators, and wheelchair seating where fixed spectator seating is provided. It also flags where a Performance Solution is needed.

Do clubhouse change rooms need accessible showers?
Part F4 links the accessible unisex shower count to showers the NCC itself requires, and the sports-venue sanitary table counts toilets, urinals and washbasins. Where team showers are provided anyway, providing an accessible unisex shower or an accessible change room with a shower is the defensible approach under the Disability Discrimination Act and is commonly required by funders.

Does a new amenities block need a Changing Places room?
Usually not under the NCC. F4D12 requires an accessible adult change facility in a Class 9b sports venue only where the design occupancy is at least 35,000 spectators or there is an accessible swimming pool with a perimeter of at least 70 metres. Councils, funders and inclusion plans may still ask for one; that is a design brief decision.

Can an access report help a grant application?
Yes. Grant programs often ask how a project will improve access. A site-specific access report or review of the existing clubhouse is evidence; a general statement that the building will be accessible is not.

How Sydney Access Consultants helps

We prepare DA and CC access reports for new and upgraded clubhouses and amenity buildings (see access reports for DA, CC and CDC), reviews of existing clubhouses, and Performance Solutions. Gary Finn is an Accredited Member of the Access Consultants Association, member 435. Our practice concentrates on Cronulla, the Sutherland Shire and Hurstville / Georges River; see Sutherland Shire access reports. Send the site plan, the architectural set and the funding or council requirements, and call (02) 9586 3111 for a fee. The free initial consultation is a plan review only.