Sydney Access Consultants prepares access reports for new shopping centres, supermarkets, centre expansions and tenancy fit-outs across NSW, from the DA through the Construction Certificate to completion access certification before the occupation certificate. We are Accredited Access Consultants, ACAA Accredited Member #435. New retail work must meet the Disability (Access to Premises - Buildings) Standards 2010 and the access provisions of the National Construction Code. In NSW that work is currently assessed against NCC 2022 Amendment 2 and AS 1428.1:2021, with NCC 2025 adopted from 1 May 2027. Our free initial consultation is a plan review only. Call (02) 9586 3111.

Why shopping centres need a whole-of-centre access strategy

A shopping centre is usually a Class 6 base building with a changing mix of tenancies, and its car park is often a Class 7a part. The Premises Standards and NCC Parts D4 and F4 apply to new work in both. The problem we see most often is drift: tenancies are designed one at a time, by different designers, and slowly move away from the base-build accessible path, the amenity counts and the signage strategy. A single access strategy for the whole centre, set at DA and carried through every stage, keeps the base build and the tenancies working together.

What the access report covers

Car park and accessible parking

The NCC sets the number of accessible car spaces by building class in clause D4D6 and its table, and AS/NZS 2890.6 governs the space, the shared zone, height clearance and signage. The report follows the continuous path from each accessible space to the centre entry, and checks that trolley bays and kerb ramps do not block it. See accessible car parking in NSW.

Entries, malls and the continuous accessible path of travel

Clauses D4D2 and D4D3 require accessible entrances and a continuous accessible path of travel to the areas the public uses. We check automatic doors and airlocks, mall gradients, ramps and step ramps against AS 1428.1 clause 10, and circulation space at doors against clause 13. See wheelchair ramp gradients and door circulation space.

Vertical access

Escalators and travelators move a lot of people, but they do not provide the accessible path of travel between levels. Where a lift is required, it has to serve the levels the public uses. See do I need a lift? and, for stairs and handrails, accessible stairways.

Sanitary facilities and accessible adult change facilities

Accessible unisex toilets and ambulant cubicles are required under NCC clauses F4D5 and F4D6; see accessible toilet requirements in NSW. Under clause F4D12, a Class 6 shopping centre must provide one unisex accessible adult change facility in an accessible part of the building when its design occupancy is not less than 3,500 people, calculated on the basis of floor area, and it contains at least two sole-occupancy units. Design occupancy is calculated under D2D18, leaving out staff-only areas and areas exempt under D4D5. The facility must be built to Specification 27 and cannot be combined with another sanitary compartment. See accessible adult change facilities and, for NCC 2025, all-gender sanitary facilities.

Signage, TGSIs, luminance contrast and hearing augmentation

Clause D4D7 sets braille and tactile signage for accessible facilities; see braille and tactile signage. Tactile ground surface indicators are needed at stairs, ramps and travelators (TGSI compliance audits), glazing and doors need visual indicators and contrast (luminance contrast), and hearing augmentation applies only where the NCC triggers it (hearing augmentation).

Supermarket-specific items

Some supermarket items are good practice and Disability Discrimination Act risk reduction rather than Deemed-to-Satisfy requirements, and the report says so plainly. They include at least one wider checkout lane with a lower counter section, accessible service and pick-up counters (see accessible counters), aisles and trolley returns kept clear of the accessible path, and an accessible route to click-and-collect points.

Base build and tenancy fit-outs: how the Premises Standards apply

The base-build report covers the common areas, car park, malls, amenities and the shell entries to each tenancy. The Premises Standards also apply to tenancy fit-outs. Part 4 of the Standards contains exceptions and concessions that can be relevant to a lessee's work in a multi-tenancy building:

The outcome depends on the project, so we assess each fit-out case by case with the certifier. The official text is on the Federal Register of Legislation. A practical step for centre managers is a tenancy access design guide, so every fit-out designer starts from the same base-build assumptions. See change of use and fit-out access and, for food tenancies, restaurant and café access reports.

DA, CC, Section 4.55 and completion: the stages

Where the Deemed-to-Satisfy path will not fit, such as long mall gradients, existing levels on an expansion or amenity locations, a Performance Solution assessed against the relevant Performance Requirements (D1P1, D1P2 or F4P1) should be settled early with the certifier. See Performance Solutions.

Expanding or refurbishing an existing centre

An expansion brings the affected part into play, and unjustifiable hardship is a last resort that is assessed on the facts of each case. An access audit ahead of a refurbishment shows what the existing centre does and does not provide before the design is fixed; see existing building access audits. Centres that rely on old approvals can also carry complaint exposure under the Disability Discrimination Act; see DDA complaints and building access.

Our shopping centre experience

Retail is one of our main project types. Sydney Access Consultants has provided access reports for new supermarket-anchored neighbourhood shopping centres in NSW, from the DA access report through to completion access certification and Section 4.55 statements; access consultancy for a city shopping plaza; a suburban shopping centre access report; and tenancy fit-outs within shopping centres, including a children's play centre in a major regional mall (access report and Performance Solution) and a specialty retail tenancy.

How to engage Sydney Access Consultants

Send the site plan, floor plans, car park layout, sections, the consent conditions or certifier request for information, and the tenancy schedule if relevant. Our free initial consultation is a plan review only. Fees are scoped per project, so call (02) 9586 3111 for a fee.

Frequently asked questions

Does a new shopping centre or supermarket need an access report in NSW?

Yes, in practice. A new shopping centre or supermarket is Class 6 work that must meet the Disability (Access to Premises - Buildings) Standards 2010 and the access provisions of the NCC, so NSW councils and registered certifiers expect a written access report at DA and a construction-set assessment at CC. NSW work is currently assessed against NCC 2022 Amendment 2 and AS 1428.1:2021, with NCC 2025 adopted from 1 May 2027.

Who needs the access report for a shopping centre tenancy fit-out?

The Premises Standards apply to tenancy fit-outs. Part 4 includes exceptions and concessions that can be relevant to a lessee's work in a multi-tenancy building, including the lessee provision in section 4.3 and the unjustifiable hardship provision in section 4.1. What needs to be assessed, and by whom, depends on the project, so work it through case by case with the certifier.

When does a shopping centre need an accessible adult change facility?

Under NCC 2022 clause F4D12, a Class 6 shopping centre needs one unisex accessible adult change facility in an accessible part of the building when its design occupancy is not less than 3,500 people, calculated on floor area, and it has at least two sole-occupancy units. The facility must be built to Specification 27 and cannot be combined with another sanitary compartment.

How is the number of accessible car spaces worked out?

By building class, using NCC clause D4D6 and its table. The spaces themselves are designed to AS/NZS 2890.6. A council DCP may also set its own rate, and the report checks both.

Do escalators count as the accessible path between levels?